Gleiter Transfer Pad
GLE04000 | MR Safe
Manual Patient Transfer
The Gleiter Transfer Pad is a lightweight manual patient-transfer device for moving a patient between beds, gurneys, and similar hospital surfaces. Its built-in side handles give trained healthcare professionals secure hand positions during the transfer workflow.
The pad contains no magnetic materials and is identified by the manufacturer as MR Safe. It can be used for transfers associated with an MR table when the facility's transfer protocol and the table manufacturer's instructions are followed.
Gleiter is a standalone patient-transfer product. It is not a stretcher, a conventional anatomical positioner, or a component included with KyphoLift or KyphoWedge.
Transfer Workflow
- Clean, disinfect, inspect, and dry the Gleiter before use.
- Place an appropriate patient sheet, chuck, or other protective layer beneath the patient.
- Using an appropriate number of trained personnel, lift the patient with the sheet or chuck onto the Gleiter without jeopardizing patient or staff safety.
- Use the Gleiter's built-in handles to move the patient to the receiving bed, gurney, or permitted imaging surface.
Specifications
| Product number | GLE04000 |
|---|---|
| Product type | Manual patient-transfer device |
| Dimensions | 78 x 30 x 1 inches |
| Product weight | 3 lb |
| Safe working load | 550 lb |
| Cover | Nylon |
| Core | High-density foam |
| MR safety | MR Safe; contains no magnetic materials |
| Intended users | Trained healthcare professionals involved in patient transfer |
| Manufacturer | KyphoLift (The Initiative LLC) |
Care and Cleaning
- Clean and disinfect the pad after each use, then wipe it with a clean, dry cloth and allow it to dry fully before storage or reuse.
- Compatible common hospital wipes include Cavi-Wipes, Sani-Cloth, Super Sani-Cloth, and Sani-Cloth Bleach.
- Alcohol-based wipes or a cloth with a properly diluted quaternary-ammonium solution may be used according to the cleaner manufacturer's directions.
- Do not immerse the foam in any liquid, sterilize the pad, use full-strength cleaning concentrate, or expose it to extreme heat.
- Store dry at 10°C to 40°C (50°F to 104°F) and below 70% relative humidity. Protect the foam from heavy objects and pressure points that could cause a permanent imprint.
Safety Information
- Read the complete instructions before use. Operation is limited to trained healthcare personnel.
- Use an appropriate sheet, chuck, or protective layer beneath the patient and enough personnel to complete the transfer safely.
- Do not use the Gleiter where there is a high potential for contact with bodily fluids.
- Inspect the pad and receiving surface before each use. Do not use the product if it is damaged, degraded, incomplete, or functioning unexpectedly.
- Do not exceed the 550 lb safe working load. Follow the MR table manufacturer's instructions when applicable.
- Repairs or modifications must be performed by an authorized specialist.
Download the Gleiter Transfer Pad GLE04000 Instructions for Use (PDF)