3D Calibration Phantom ATS 560H

The Model 560H rubber-based, tissue-mimicking (TM) phantom is designed to provide a basic means of evaluating an imaging system’s performance and its 3D volumetric measurements.

The phantom is designed with a combination of monofilament line targets. six non-echogenic cylindrical targets of varying sizes and a 3D egg-shaped target structure. The monofilament line targets have a diameter of 0.12 mm, to optimize the displayed image at frequencies ranging from 2.25 to 7.5 MHz. Four groups of line targets are provided to evaluate the vertical and horizontal calibration measurements, axial-lateral resolution and the dead zone.

**Lifetime warranty**

  Tests Performed
   • Dead Zone or Ring-Down
   • Vertical Measurement
     Calibration 
   •
Horizontal Measurement
     Calibration
   • Sensitivity/Penetration
   • Functional Resolution  
   •
Focal Zone  
   • Axial & Lateral Resolution
 
   •
Image Uniformity
   • Volume Measurement

  Uses:
   •
Quality Assurance  
   •
Basic Clinical Performance
   • In-Process Manufacturing

   • 3D Volume Measurement

  
• Teaching

Specifications

General
Overall Dimensions 23.4 x 20.5 x 9.5cm
Weight 3.1 Kg
Scan Surfaces 4
Scan Surface Dimensions 17 x 8 cm 19 x 8 cm
Tissue Mimicking Material
Type Urethane rubber
Freezing Point < -40°C
Melting Point > 100°C
Attenuation Coefficient 0.5 dB/cm/MHz ± 5.0%
Speed of Sound 1450 m/s ±1.0% at 23°
Line Targets
Material Monofilament Nylon
Diameter 0.12mm ± 5%
Vertical Group

Number of Targets

Interval Spacing

Depth

17

1.0 cm

1.0 - 18.0 cm

Horizontal Group

Number of Targets

Number of Groups

Interval Spacing

Depth

Scanning Surface #1

Scanning Surface #3

10

2

2.0 cm

 

5.0 cm

5.0 cm

Dead Zone Group

Number of Targets

Lateral Displacement

Depth

Interval Spacing

9

5.0 mm

2.0 - 10.0 mm

1.0 mm

Axial-Lateral Resolution Group

Number of Targets

Lateral Displacement

Interval Spacing

Axial Depths

Lateral Depths

Depth

6

1.0 mm

5.0, 4.0, 3.0, 2.0, 1.0 mm

5.5 & 12.5 cm

5.5 & 14 cm

7.0, 11.0, 4.0, 16.0 cm

Anechoic Target Structures
Type Non-echogenic, cylindrical
Number of Targets 6
Targets:

Group 2, 3, 4

Group 6, 8

 

17

8

Diameters 4, 8, 10 mm
Interval Spacing

(center to center)

1.0 cm
Depth 3, 5, 12, 15 cm
3D Target Structure
Type Echogenic, Egg-shaped structure
Number of Targets 1
Dimensions Length: 70 mm

Width: 50 mm

Volume 91.6 cm3
"Lifetime warranty"

 

   

    

Supertech ®

 

  Address:
  P.O. Box 186
  Elkhart, IN 46515 USA


  Sales: 800-654-1054
  Phone: 574-264-4310
  Fax: 574-264-9551


Email:
sales@supertechx-ray.com
Support: support@supertechx-ray.com