Supertech ®
Thousands of Products
Serving You is Our Pleasure
Product Categories
Multipurpose Phantom ATS 514
Tests Performed • Dead Zone or Ring-Down
• Vertical Measurement Calibration
• Horizontal Measurement Calibration
• Axial and Lateral Resolution
• Sensitivity
• Functional Resolution
• Definition and Fill-in
• Gray Scale & Displayed Dynamic RangeUses
• Quality Assurance
• Clinical Performance
• In-Process Manufacturing
• Final Q.A. Inspection
• Research & Development
• Teaching
The Model 514 Multipurpose Phantom is composed of a hydrogel-based material which acoustically mimics human tissue. The phantom is contained in an acrylic housing to provide strength and permanence. A soft polyurethane film with an impedance closely matching that of human skin is used for the scan window, thereby allowing easy transmission of the ultrasound beam into the phantom. A built-in scanning well is provided to allow the use of water as the coupling medium. However, coupling gels may be used if desired.
The phantom is designed specifically to evaluate the performance of sector scan, linear, phased and annular array ultrasound imaging systems.
Specifications
General Overall dimensions
23.5 x 22.4 x 9.7 cm* Weight 5.33 Kg* Housing Material
Acrylic Scan Surface
1 Scan Surface Material Polyurethane Membrane Scan Surface Dimensions
22.0 x 8.0*
Tissue Mimicking Material Type Hydrogel Freezing Point
0° C Melting Point
49° C Speed of Sound
1540 m/s ± 1.0% at 23° C Attenuation Coefficient 0.5 db/cm/Mhz ± 5.0% Scan Surface Dimensions
22.0 x 8.0*
Line Targets Material
Monofilament nylon Diameter 0.12 mm ± 5.0% Dead Zone
Number of Targets
6 Lateral Displacement 5 mm ± 0.1mm Depth 5 to 10 mm ± 0.1mm Vertical Group Number of targets 23 Interval Spacing Depth .5 cm ± 0.1mm
1.0 - 5.0 cmInterval Spacing Depth 1.0 cm ± 0.1mm
5.0 - 20.0 cmAnechoic Target Structure Type Non-echogenic, cylindrical Positional Tolerance ± 0.1mm Diameter Tolerance ± 5 % Number of Groups 5 Diameters
Interval Spacing
(center to center)
Depth of 1.0 - 3.0 cm
Depth of 3.0 - 20.0 cm
2, 3, 4, mm
1.0 cm
2.0 cmDiameters
Interval Spacing
(center to center)
Depth of 2.0 - 20.0 cm
6.0, 8.0 mm
2.0 cm
Horizontal Number of Groups
3 Target per group
5 Depth
3.0, 8.0 12.0 cm Interval Spacing 1.0 cm Axial-Lateral Resolution Number of Group 3 Target per group 10 Depth 3.5, 7.0, 12.0 cm Lateral Displacement 1.0 mm ± 0.1mm Axial Spacing 4, 3, 2, 1, .5 mm Lateral Spacing 4. 3, 2, 1 mm
Gray Scale Target Structures Type
Number of Targets
Diameter
DepthEchogenic cylindrical
4
10 mm ± 5.0 %
4 cm ± 1.0 mmContrast relative to the
background material (dB)+6, +3, -3, -6
*Nominal dimensions
WARRANTY One Year
Supertech ®
Address:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com
Support: support@supertechx-ray.com