Supertech ®
Thousands of Products
Serving You is Our Pleasure

Home

Registered w/
Dun & Bradstreet 

VOSB - Veteran Owned Small Business since 1973   NAICS CODE: 423450


Product Categories

 
  Supertech's
  X-ray Technique Calculator
  Alderson Phantoms
  Anesthesiology
  Anthropomorphic Phantoms
  Aprons and Barriers
  BIODEX Tables
  Breast Imaging/Care/Mammo
  Chairs
  CT
  Eyewear
  Filters
  First Resp./Homeland Security
  L-Blocks and Shields
  Mammography
  MRI
  Multi-Modality Phantoms
  Nuclear Medicine
  Patient Positioning
  Quality Control Instrumentation
  Radiation Survey Meters
  Radiation Therapy
  Radiopaque Rulers
  Ultrasound
  X-Ray Technique Calculator
  Continuing Ed / CEU
 

IMRT Head and Torso Freepoint Phantom
Complete QA from CT imaging to dose verification

Model 002H9K

Features

  • Ionization chambers, TLD, MOSFET and Diodes easily
    positioned using interchangeable rods
  • Choose any point dose location by rotating the cylinders
  • Use radiographic film dosimetry1 - Ready Pack® and/or   GafChromic® film
  • Close placement of detectors to film improves
    film calibration
  • CT - film markers ensure accurate film to plan
    registration
  • Surfaces are etched with indices for precise alignment
  • Configure with or without heterogeneities
 
CIRS offers a variety of IMRT phantoms to match the most common IMRT treatment areas such as prostate, head and neck, breast and lung.

All CIRS IMRT Phantoms are manufactured from proprietary materials that faithfully mimic water, bone and lung within 1% from 50 keV to 25 MeV. These unique materials eliminate the need for correction factors, thus improving accuracy and saving time. The phantoms simulate the patient through the entire process from CT data acquisition and planning to delivery and dose verification.

The new Model H9K was designed in collaboration with David D. Loshek PhD. With the H9K, choose any point dose location within a circular area with diameter of 11.2 cm by simply adjusting the two rotating cylinders. Lung and bone equivalent rods can be positioned at any location within the circular area for assessment of heterogeneity correction. Remove the center cylinder from the phantom body to simulate head and neck set-ups.

     Supertech ®

  President: David B. McNitt
  V.P. of Marketing: Judy McNitt-Mell
  Asst. to the President: Joy E. Nystrand

  Address:
  P.O. Box 186
  Elkhart, IN 46515 USA


  Sales: 800-654-1054
  Phone: 574-264-4310
  Fax: 574-264-9551


Email:
sales@supertechx-ray.com
Support: support@supertechx-ray.com