Mammography Research Set Model 012A
Designed to encompass the full range of size, glandularity
and thickness encountered in clinical mammography.

 

 

Features

  • Enable evaluation of image quality under varying degrees of thickness and glandularity
     

  • Provides accurate reliable test for radiation dose
     

  • Assures consistent production of diagnostically useful images

 

 

The CIRS mammography research set includes tissue equivalent phantoms 4, 5 and 6 cm thick. Each phantom contains identical embedded details (see map 011A). The glandular content of each phantom is 50%, 30%, and 20% respectively. Also included are phototimer compensation plates enabling a range of thickness from 0.5 cm to 7 cm with a glandular content of 30%, 50% and 70%.

One compensation plate contains embedded details for evaluation of image quality. A 30 power hand held microscope and heavy duty foam lined carrying case are included.

CIRS resin material mimics the photon attenuation coefficients of a range of breast tissues. Average elemental composition of the human breast being mimicked is based in the individual elemental composition of adipose and glandular tissue reported by Hammerstein.
 

Attenuation coefficients are calculated by using the "mixture rule" and the Photon Mass Attenuation and Energy Absorption Coefficient Table of J.H. Hubbell.

The methodology and design of these phantoms was developed by Dr. Panos Fatouros and his associates at the Medical College of Virginia.
 