Supertech ®
Thousands of Products
Serving You is Our Pleasure
Product Categories
Direct measurement of Wave Pulse & Exposure TimeECC Digital X-ray Pulse Counter 8700
The Model 8700 X-Ray Pulse Counter/ Exposure Time Meter is used to measure the time or duration of radiation output produced by a wide variety of x-ray generators. The x-ray sensor in the 8700 allows direct measurement of exposure from the x-ray head. Pulses produced by half-wave and full-wave x-ray are measured as 60 or 120 pulses per second. For DC, capacitor discharge and 3-phase x-ray, the 8700 measures the exposure time in milliseconds.
When testing x-ray timers and controls, the time of relay contact can be measured using the AC input feature.
The Model 8700 is "self-resetting". There is no need to reset the instrument after each reading. The reading is stored after each exposure, holding until the next exposure.
New and Improved!
We have recently made significant changes to the design of our Model 8700 to improve the function and accuracy. No changes were made regarding the actual operation, so the units work the same as existing models.
However, the following performance improvements were made:
Wider Range
Increased sensitivity allows use with lower power x-rays
Wider dynamic range allows use with higher power x-rays
More accuracy on DC/Multiphase high power x-rays
Measurement ends at 70% of peak value eliminating inaccuracy due to slow tail.
New circuitry saves production time and parts cost, allowing us to keep our competitive prices.
Low power circuitry improves battery life.
Features
Small hand-held size
AC or DC X-Rays
New high accuracy circuit
Self-resetting
Battery operated
Two year warranty
Direct exposure reading or AC input
Use for Medical or Dental X-Rays
Remote Sensor option
No periodic calibration needed
Custom carrying case option
Durable ABS plastic case
Typical Applications
Measurement of Exposure
Quality Assurance
Verification of X-ray Exposure Time
Calibration of X-ray Timer
Direct Measurement of Timer Accuracy
Troubleshooting and Repair of x-ray
Specifications
ACCURACY: AC - one count
DC- 2% +/-1 millisecondSENSITIVITY: X-ray input: 40kVp, 5mA at 5 cm from top surface of
case, pointed to target
AC Input: 90 VAC minimumRANGE: 9999 Pulses
9999 MillisecondsDISPLAY: 0.4" Liquid Crystal
POWER: Internal 9 Volt Battery, Low Battery Indicator
BATTERY LIFE: 48 hours continuous, typically 9 months of normal use
CONTROLS / INDICATORS
Three position switch: Pulse, Off, Milliseconds
4 digit liquid crystal display: 0.4" characters, Low battery indicator
Oscilloscope output
Remote Sensor InputPHYSICAL SIZE: 80 x147x 40mm, 3.15 x 5.8 x1.6 inches
CONNECTIONS: None required for direct exposure measurement
2 tip jacks for AC input
Jack for Remote Sensor Option
Jack for Oscilloscope Output
X-ray Pulse Counter / Exposure Time Meter 8700 OPTIONAL ACCESSORIES
Remote Sensor with 3 meter cable allows operation of Pulse Counter away from x-ray 8700RS Padded Cordura Carrying Case Carrying case specifically designed for instrument 8700CC Oscilloscope Interface Cable connects ‘Scope’ output to standard BNC oscilloscope input. Allows radiation output waveform to be viewed on an oscilloscope 8700SC Hard shell Carrying Case 8700HC
Supertech ®
Address:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com
Support: support@supertechx-ray.com