Ion Chamber Survey Meter with Beta Slide
- High sensitivity measurements of exposure and exposure rate
- Available with dose equivalent energy response (SI units)
- Fast response to measure
radiation from leakage, scatter beams and pinholes- Ergonomic, anti-fatigue handle with replaceable grip and wrist strap
- Sliding shield for alpha and beta discrimination
- Excel add-in for Windows® for data logging and selection of instrument operating parameters (optional)
- Low noise chamber bias supply for fast background settling time
- Choice of bright, highly visible colors
- Easy touch keys
INTRODUCTION
The Model 451B state-of-the-art ion chamber survey meter is a hand-held battery operated unit designed for use in both rugged and normal environments. The
Model 45 1B measures alpha, beta, gamma and X-ray radiation. The Model 45 1B employs microprocessor and LCD technology and features a rugged ionization chamber with a mylar window and protective steel mesh. An integral beta shield serves as an equilibrium thickness for photon measurements. The ergonomic handle, features a large diameter cushioned grip and is designed to reduce fatigue associated with extended use. The case is constructed of lightweight, high strength materials and is sealed against moisture. The user must specify R or Sv when ordering.The display features an analog bar graph, 2 1/2 digit digital readout, low battery
and freeze mode indicators. User controls consist of an ON/OFF button and a
MODE button. The unit is auto-zeroing and auto-ranging. The display features
circuitry that automatically activates the backlight in low ambient light conditions.The RS-232 interface can be connected directly to a computer for use with the ' Freeze indicates peak reading Excel add-in for Windows®, enhancing the functionality of the instrument. The software allows for data retrieval, user parameter selection and provides a virtual instrument display with audible (requires sound card) and visual alarm indication. The software may be customized by the user for specific applications.
APPLICATIONS
The Model 451B is ideal for site surveys and a wide range of medical and health physics applications. It is regularly used by Police and Fire Departments, X-ray manufacturers, government agencies, state inspectors, emergency response and HAZMAT teams, nuclear medicine labs, hospital radiation safety officers, and nuclear power industry.
FEATURES
- Ideal for a wide range of applications
including NDT, X-ray, and environmental- Battery operated
- Auto-ranging and auto-zeroing
- RS-232 communications interface
- Measures rate and dose simultaneously
- Tripod mount for stationary, area
monitor applications- Freeze mode indicates peak reading
- Programmable flashing display and audible alarm
- Automatic, ultra-bright LCD display
- Excel add-in for Window® (optional)
- Real-time data logging
- Downloading of 2700 data sets stored in instrument
- Virtual instrument display with audible and visual alarm indication
- Supports user instrument configuration and parameter selection
- User selectable modes
SPECIFICATIONSRadiation Detected
Alpha above 4 MeV
Beta above 100 keV
Gamma above 7 keVOperating Ranges
Accuracy
Within 10% of reading between 10% and 100%
of full scale indication on any range, exclusive
of energy response. Calibration source is 137CsDetector
Chamber: 349 cc volume air ionization
Chamber wall: 246 mg/cm2 thick phenolic
Chamber window: 1.7 mg/cm2 mylar, protected
by steel mesh, 46 cm2 detection area
Beta slide: 440 mg/cm2Controls ON/OFF and MODE
Automatic Features
Auto-zeroing, auto-ranging, and auto-backlight
Response Time
Power Two 9-volt alkaline, 200 hours operation
Display LCD analog/digital with backlightAnalog
100 element bar graph 6.4 cm long. Bar graph is divided into 5 major segments, each labeled with
the appropriate value for the range of the instrumentDigital
2 1/2 digit display is followed by a significant zero digit depending on the operating range of the instrument. The units of measurement are indicated on the display at all times. Digits are 114 in (6.4 mm) high. Low battery and freeze indicators are also provided on the display
Warm-up Time One minute
EnvironmentalTemperature Range - 40°C to + 70°C
Relative Humidity 0 to 100%, @ + 60°C
Geotropism Less than 1%
Typical Energy Dependence
Dimensions 4 in (w) x 8 in (d) x 6 in (h) (10 x 20 x 15 cm)
Weight 2 lb 7 oz (1.11 kg)
451 B Models
Model 451B-RYR 45 1B w/standard chamber
Model 451B-YGG 451B w/standard chamber
Model 451B-DE-SI-RYR 451 B w1Dose
Equivalent chamber
Model 451B-DE-SI-YGG 45 1B w1Dose
Equivalent chamber
Suffix designation RYR = Red/yellow/red
Suffix designation YGG = Yellow/gray/grayOptions
Model 451EXL Excel add-in software and RS-232 interface cable
Model 190HPS Single unit carrying case
Model 190HPC Multiple unit carrying case
Model 451UCS 238Uranium .064 µC check source, impregnated 2 in x 2 in yellow cardModes
Integrate mode operates continuously 30 seconds after the instrument has been turned on.
Integration is performed even if the instrument is displaying in mR/h or R/hFreeze mode will place a tick mark on the bar graph display to hold on the peak displayed value. The unit will continue to read and display current radiation values
Pressurized µR Ion Chamber Survey Meter
- High sensitivity µR measurements of exposure and exposure rate
- Available with dose equivalent energy response (SI units)
- Fast response to measure
radiation from leakage, scatter beams and pinholes- Ergonomic, anti-fatigue handle with replaceable grip and wrist strap
- Excel add-in for Windows® for data logging and selection of instrument
operating parameters (optional)- Low/noise chamber bias supply for fast background reading
- Choice of bright, highly visible colors
- Easy touch keys
INTRODUCTION
The Model 451P state-of-the-art ion chamber survey meter is a hand-held battery operated unit designed for use in both rugged and normal environments. The Model 451P features a pressurized ionization chamber, providing enhanced sensitivity and improving energy response to measure gamma and X-ray radiation.The Model 451P employs microprocessor and LCD technology. The ergonomic handle, features a large diameter cushioned grip and is designed to reduce fatigue associated with extended use. The case is constructed of lightweight, high strength ' RS - materials and is sealed against moisture. The user must specify R or SV when ordering.
The display features an analog bar graph, 2 1/2 digit digital readout, low battery and freeze mode indicators. User controls consist of an ON/OFF button and a MODE button. The unit is auto-zeroing and auto-ranging. The display features circuitry that automatically activates the backlight in low ambient light conditions.
The RS-232 interface can be connected directly to a computer for use with the Excel add-in for Windows®, enhancing the functionality of the instrument. The software allows for data retrieval, user parameter selection and provides a virtual instrument display with audible (requires sound card) and visual alarm indication. The software may be customized by the user for specific applications.
APPLICATIONS
The Model 451P is used in a wide range of medical and health physics applications. The Model 451P was designed to measure leakage and scatter around diagnostic X-ray and radiation therapy suites. Also, the Model 451P is ideal for site surveys and is regularly used by X-ray manufacturers, government agencies, state inspectors, research labs, biomedical technicians, and in airports for baggage inspection equipment maintenance.
FEATURES
- Ideal for a wide range of applications including NDT, X-ray, and environmental
- Battery operated
- Auto-ranging and auto-zeroing
- RS-232 communications interface
- Measures rate and dose simultaneously
- Tripod mount for stationary, area monitor applications
- Freeze mode indicates peak reading
- Programmable flashing display
- Automatic, ultra-bright LCD display
- Separate integrate mode
- Excel add-in for Window® (optional)
- Real-time data logging
- Downloading of 2700 data sets stored in instrument
- Virtual instrument display with audible and visual alarm indication
- Supports user instrument configuration and parameter selection
- User selectable modes
SPECIFICATIONS
Radiation Detected
Beta above 1 MeV
Gamma and X-rays above 25 keVOperating Ranges
AccuracyWithin 10% of reading between 10% and 100%
of full scale indication on any range, exclusive
of energy response. Calibration source is 137CsDetector
Chamber: 300 cc volume pressurized air
ionization chamber to 6 atmospheresControls ON/OFF and MODE
Automatic Features
Auto-zeroing, auto-ranging, and auto-backlight
Response Time
Analog response time from 10% to 90% of
reading for a full scale step increase is dependent
on operating range. Response time for a step
increase in radiation exposure rate from
background:
The following table shows time measured from 10% to 90% of final value
for a step increase or decrease in exposure rate such that a range change
does not occur. These values are the response times for the various ranges:
Power Two 9-volt alkaline, 200 hours operation
Display LCD analog/digital with backlight
Analog
100 element bar graph 2.5 in (6.4 cm) long. Bar graph is divided
into five major segments, each labeled with the appropriate value
for the range of the instrumentDigital
2 1/2 digit display is followed by a significant zero digit depending on
the operating range of the instrument. The units of measurement are
indicated on the display at all times. Digits are 1-1/4 in (6.4 mm) high.
Low battery and freeze indicators are also provided on the display
Warm-up Time
Less than two minutes for initial operation when
the instrument is in equilibrium with ambient temperature
EnvironmentalTemperature Range - 20°C to + 50°C
Relative Humidity 0 to 100%
Geotropism NegligibleTypical Energy Dependence
I6Nitrogen gamma rays are 110% to 120% of indicated readings
as determined at the University of Lowell
Dimensions 4 in (w) 8 in (d) 6 in (h) (10 x 20 x 15 cm)
Weight 2 Ib 6 oz (1.07 kg)
451 P Models
Model 451P-RYR 451P w/standard chamber
Model 451P-YGG 451P w/standard chamber
Model 451P-DE-SI-RYR 451P w/Dose Equivalent chamber
Model 451P-DE-SI-YGG 451P w/Dose Equivalent chamberSuffix designation RYR = Red/yellow/red
Suffix designation YGG = Yellow/gray/grayOptions
Model 451EXL Excel add-in for Windows® and RS-232 interface cable
Model 190HPS Single Unit Carrying Case
Model 190HPC Multiple Unit Carrying Case
Model 62-103 137Cs10 µCi Check SourceModes
Integrate mode operates continuously 30 seconds after the instrument has been turned on. Integration is performed even if the instrument is displaying in mR/h or R/h
Freeze mode will place a tick mark on the bar graph display to hold on the peak displayed value. The unit will continue to read and display current radiation values
Supertech ®
President: David B. McNitt
V.P. of Marketing: Judy McNitt-Mell
Asst. to the President: Joy E. NystrandAddress:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com
Support: support@supertechx-ray.com