Supertech ®
Thousands of Products
Serving You is Our Pleasure
Product Categories
Rad-Check Plus
"The original" x-ray exposure meter
Introduction
Proven RAD-CHECK technology specifically designed to provide you with the ultimate in versatility and cost-effective operation.
Accurate, lightweight, portable . . . this "industry standard" enable you to gain the critical edge in your QC program.
Applications
Battery operation and built-in detector virtually eliminate setup time. Just place the meter or external ion chamber on x-ray table; collimate, shoot, and read the result.
Precision ion chamber and digital display ensure accuracy plus easy readability.
Rad Check Plus can perform:
- Entrance skin exposure measurements (ESE)
- Fluoroscopy exposure measurements
- Exposure checks; radiographic (mR/mAs)
- Beam quality; half value layer (HVL)
- mAs reciprocity; mA station checks . . . plus many others, depending on the remote external chambers used
- The American College of Radiology (ACR) recommends this type of product in their quality assurance program
Features
- Fast and easy-to-use. Battery operation and built-in detector eliminate setup time
- Measures dose up to 2 R; dose rate up to 20 R/min
- Energy response is ± 5 % from 30 to 150 kVp for the RAD-CHECK PLUS internal chamber
- Optional remote chambers for mammographic and cine imaging systems
- Extremely compact . . . 6 x 6.25 x 2.75 inch; weighs only 1.125 lb
Specifications
Ranges 0.001 to 2 R, 0.01 to 20 R/min
Internal chamber 30 cc volume, energy response ± 5% from 15 to 65 kcV (30 to 150 kVp filtered). 20.5 cm2 (5.1 cm ø) effective measurement area. Center of chamber 1.03 cm below top of chamber
Standard calibration At 75 kVp with 4 mm A1 filtration at 22°C and one atmosphere
Reproducibility Within 2% short-term over 100 mR to 2 R range (1 to 20 mGy)
Electrometer drift 0.5 to 1 mR/min typical; 6 mR/min maximum (5 to 10 µGy/min maximum)
Maximum exposure rate Minimum 90% collection efficiency at 20 R/sec
Automatic reset Resets display to zero; can also be reset manually
Operating temperature 10 to 40°C
Relative humidity 0 to 90%, non-condensing
Display 3.50 x 0.50 inch LCD, low battery indicator
Controls Auto or manual reset selector. Display zero reset button. Dose or dose rate output selector. Integral or remote ion chamber selector. On/off switch
Power requirements 9 V alkaline battery, > 100 hours operation (50 hours in manual reset mode)
Dimensions 6 (w) x 6.25 (d) x 2.75 in (h) (15.25 x 15.9 x 7 cm)
Weight 1.125 lb (0.51 kg)
Optional accessories
Radiographic Ion Chamber, 30 cm3 (Victoreen Model 6000-528): energy response: within 7% from 30 to 150 kVp (15 to 65 keV); cable: 15 ft(4.5 m); chamber dimensions: 4 x 4 x 0.54 in thick (10.2 x 10.2 x 1.4 cm)
Mammographic Ion Chamber, 3.3 cm3 (Victoreen Model 6000-529): energy response: within 5% from 0.2 to 5.0 mm A1 HVL (16 to 90 kVp); cable: 15 ft (4.5 m); chamber dimensions: 4 cmøx1.5 cm thick. This chamber meets the needs of the MQSA for an external transparent chamber. Option: Probe Holder (Model 6000-529-95) for BRH2 test stand.
CT Ion Chamber, 3.2 cm3 (Victoreen Model 6000-100): energy response: ± 5% from 1 to 10 mm A1 HVL; cable: 3 ft (0.9 m); sensitive length: 4 in (10.0 cm); chamber inside ø: 0.25 in (6.4 mm)
Image Intensifier Ion Chamber, 150 cm (Victoreen Model 6000-530B): energy response: ± 10%from 1.8 to 10 mm A1 HVL; cable: 10 ft (3.0 m); chamber dimensions: 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm)
Carrying Case (Model 89-525): holds RAD-CHECK PLUS and accessories
Available model(s)
06-526 Rad-Check Plus
06-526-2200 Rad-Check Plus, SI Units
Supertech ®
Address:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com