Supertech ®
Thousands of Products
Serving You is Our Pleasure
Product Categories
4000 Series Non-Invasive X-Ray Test Devices
X-Ray Test Device Victoreen® Model 4000M+
- Measures kVp maximum, kVp average, kVp effective, dose and time in one exposure
- Compact, lightweight design
- Displays R or Gy
- External ion chambers for Mammo, CT, image intensifier and phototiming measurements
- Automatic exposure reset for hands-off operation
- Rechargeable Ni-Cd batteries provide more than six hours of continuous service
- RS-232 computer interface
- Storage scope output for real-time waveform display
- Reversible display
Introduction
The Model 4000M+ does it all. Simply place the instrument in the x-ray beam, make one exposure, and it serially displays kVp
Maximum, kVp Average, kVp Effective, dose, and time. The Model 4000M+ then automatically resets for the next exposure. A CsI
photodiode pair provide the kVp measurements through five user-selectable filter pairs. This ensures optimum accuracy over the
entire diagnostic range with minimum filtration dependence. Exposure measurements are made with a parallel plate ionization chamber
located above the filter wheel. Exposure time is measured with quartz crystal accuracy. Plus, a variety of external ion chambers may
be connected for even greater flexibility.
Specifications
Kilovoltage
Accuracy
1 kV Mo/Mo (22 to 35 kVp)
(Mammo generators w/30 μ Mo)
Range
W/Al Tubes: 27 to 155 kVp
Mo/Mo Tubes: 21 to 50 kVp
Time
Measured during entire exposure
at 90% rise/fall of waveform
Accuracy Within 2% or 2 ms,
whichever is greater
Range 1 ms to 10 seconds
Exposure
Measured during entire exposure;
kVp corrected
Accuracy ± 5%
Range 10 mR to 10 R
Fluoroscopic rate
Measured over one second
intervals during fluoro exposure
Accuracy ± 5%
Range 0.5 to 200 R/minDetectors
kV CsI/photodiode pair measures
x-ray transmission through
differential attenuators
Time Computed from kV waveform
stored in memory against quartz crystal
time base
Exposure Parallel plate ionization chamber
Volume 36 cm3
Window 38 mg/cm2, 18.9 cm2 Polycarbonate
Calibration Reference to a NIST traceable
voltage divider and a calibrated exposure
monitor during irradiationPhysical
Display 16 character dot-matrix LCD
Controls Model 4000+ Five rocker switches
On/Off Power switch
Radio/Fluoro Select radiographic or fluoro operation
High/Low Select for sensitivity
Roll Roll thru data
Exposure/All Select exposure only for external ion chamber
Mo/Mo or W/Al Select anode/filter of x-ray tube
Connectors
Power 9 VDC, 500 mA
Scope BNC for oscilloscope connection
RS-232 DB-9 connector configured as DCE. BNC and banana
plug for external Ion chamber
Power requirements 9 VDC 500 mA external supply
Rechargeable internal Ni-Cd batteries supply more than six hours of
continuous service with overnight charge
Dimensions 8.5 (w) x 9 (d) x 3 in (h) (21.5 x 23 x 7.6 cm)
Weight Approximately 3.5 lb (1.59 kg)
HVL set Aluminum filters: 2.3, 1.0, and 0.3 mm
External chamber accessories
Radiographic Ion Chamber, 30 cm3 (Victoreen Model 6000-528):
energy response: within 7% from 30 to 150 kVp (15 to 65 keV);
cable: 15 ft (4.5 m);
chamber dimensions: 4 x 4 x 0.54 in thick (10.2 x 10.2 x 1.4 cm)
Mammographic Ion Chamber, 3.3 cm3 (Victoreen Model 6000-529): energy response: within 5% from 0.2 to 5.0 mm Al HVL (16 to 90 kVp);
cable: 15 ft (4.5 m);
chamber dimensions: 4 cm Ø x 1.5 cm thick. This chamber meets the needs of the MQSA for an external transparent chamber.
Option: Probe Holder (Model 6000-529-95) for BRH2 test standImage Intensifier Ion Chamber, 150 cm3 (Victoreen Model 6000-530B): energy response: ± 10% from 1.8 to 10 mm Al HVL;
cable: 10 ft (3.0 m);
chamber dimensions: 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm)
Scatter Ion Chamber, 400 cm3 (Victoreen Model 6000-532B)
energy response: ± 5% from 32 to 850 keV; cable 10 ft (3.0 m);
chamber dimensions: 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm)
CT Ion Chamber, 3.2 cm3 (Victoreen Models 6000-100 and 500-100): energy response: ± 5% from 1 to 10 mm Al HVL;
cable: 3 ft (0.9 m); sensitive length: 4 in (10.0 cm);
chamber inside Ø: 0.25 in (6.4 mm)
CT High Sensitivity Ion Chamber, 10 cm3, for multislice CT
(Victoreen Models 6000-200 and 500-200):
energy response: ± 5% from 1 to 10 mm Al HVL; cable: 3 ft (0.9 m);
sensitive length: 4 in (10.0 cm); chamber inside Ø: 0.45 in (11.44 mm)Available model(s)
4000M+ X-Ray Test Device
Available AC adapters (specify with order)
Model Description Typical geo.
region14-301 110 VAC 9 VDC 500 mA USA, Japan 14-399 230 VAC 9 VDC 500 mA Europe 14-415 230 VAC 9 VDC 500 mA UK 14-415 and
14-416 adapter230 VAC 9 VDC 500 mA Australia
Optional accessories
4000 Toolkit for Excel (Model 4000EXL)
Ultra-High Purity HVL Attenuators (Model 07-434): for mammo,
set of 6
Carrying Case (Model 4000-69)
RS-232 Cable, 25 ft (7.6 m), 9-pin to 9-pin (Model 190004)
4000 Toolkit for Excel Victoreen® Model 4000EXL
- Automatically collects measurement results and places them in an Excel worksheet
- Captures radiation and kV waveforms and charts them in an Excel worksheet
- Templates are provided for QA tests on radiographic, fluoroscopic, and mammographic x-ray machines
- Templates may be modified to perform user specific tests and generate user customized reports
Introduction
Features
The 4000 Toolkit for Excel is a complete software package for the 4000M+ NERO® that includes an Excel Add-In, called 4000 Add-In and Excel templates that may be used to evaluate the performance of radiographic, mammographic and fluoroscopic x-ray machines. The 4000 Add-In collects measured results from the 4000M+ NERO and places the data in the
cells of the active Excel worksheet, starting at the active worksheet cell. The 4000 Add-In also may be used to acquire and graph radiation and kV waveforms from the 4000M+ NERO as well as remotely control the 4000M+ NERO.
- Allows complete remote control of the Model 4000M+ NERO
- Complete on-line help speeds learning
- Compatible with Windows® 95, 98, ME®, NT® 4.0, 2000, and Microsoft® Excel 95,
97, 2000- Automatically detects the presence of Model 4000M+ NERO
Specifications
Controls
The 4000 menu provides an interface for the user to remotely control the 4000M+ NERO and retrieve radiation and kV waveforms.
A description of each menu option follows:
Remote Control…
Selects the 4000M+ NERO measurement mode and measurement options. This allows the user to select the correct measurement mode for the template in use. For instance, the radio mode is selected when using the radiographic template, the Mo/Mo target filter is selected when using the mammographic template and the fluoro mode is selected when using the fluoroscopic template
Retrieve Rad Waveform
Retrieves the radiation waveform data from the 4000M+ NERO and charts it in a new Excel chart
Retrieve kV Waveform
Retrieves the kV waveform data from the 4000M+ NERO and charts it in a new Excel chart
Templates
Three templates are also provided with the 4000 Toolkit for Excel:
a radiographic template, a mammographic template and a fluoroscopic template. Each template includes a help worksheet with detailed instructions for its use. The 4000 Radiographic Template is used to perform the following radiographic tests:
- Reproducibility
- kVp Accuracy
- Timer accuracy
- Linearity
Beam quality
The 4000 Mammographic Template may be used to perform mammography tests required for ACR and MQSA. Measured data from the Model 4000M+ NERO may be automatically collected in the following worksheets:
kVp accuracy
kVp reproducibility
Beam quality
Breast entrance exposure
AEC reproducibility
Average glandular dose
Radiation output rate
The 4000 Fluoroscopic template is used to perform the following fluoroscopic tests:
kVp accuracy
Beam quality
Fluoro exposure rate
These templates are easy to use and can be modified to fit the user’s needs
System requirements
• Windows 95, 98, ME, NT 4.0, 2000
• Microsoft Excel 95, 97, 2000
• One serial port (COM1 through COM4)
Available model(s)
4000EXL 4000 Toolkit for Excel
Supertech ®
President: David B. McNitt
V.P. of Marketing: Judy McNitt-Mell
Asst. to the President: Joy E. NystrandAddress:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com