Supertech ®
Thousands of Products
Serving You is Our Pleasure

Home

Registered w/
Dun & Bradstreet 

WOSB - Woman Owned Small Business
Established 1973


Product Categories

 
  Supertech's
  X-ray Technique Calculator
  Alderson Phantoms
  Anesthesiology
  Anthropomorphic Phantoms
  Aprons and Barriers
  BIODEX Tables
  Breast Imaging/Care/Mammo
  Chairs
  CT
  Filters
  First Resp./Homeland Security
  L-Blocks and Shields
  Mammography
  MRI
  Multi-Modality Phantoms
  Nuclear Medicine
  Patient Positioning
  Quality Control Instrumentation
  Quality Control Phantoms
  Radiation Protection Eyewear
  Radiation Survey Meters
  Radiation Therapy
  Radiopaque Rulers
  Ultrasound
  X-Ray Technique Calculator
 
 

Quality Control Systems

Victoreen 4000M+ X-ray Test Device

4000EXL Toolkit for Excel

07-434 Ultra-High purity HVL Attenuators
 

Victoreen 4000M+ X-ray Test Device
                     
Non-Invasive

Click Here to Secure Financing

 

 

 

The Victoreen® X-Ray Test Device, Model 4000M+ does it all. Simply place the instrument in the x-ray beam, make one exposure, and it serially displays kVp Maximum, kVp Average, kVp Effective, dose, and time. The Model 4000M+ then automatically resets for the next exposure. A CsI photodiode pair provide the kVp measurements through five user-selectable filter pairs. This ensures optimum accuracy over the entire diagnostic range with minimum filtration dependence. Exposure measurements are made with a parallel plate ionization chamber located above the filter wheel. Exposure time is measured with quartz crystal accuracy. Plus, a variety of external ion chambers may be connected for even greater flexibility.

Key Features

  • Measures kVp maximum, kVp average, kVp effective, dose and time in one exposure
  • Compact, lightweight design
  • Displays R or Gy
  • External ion chambers for Mammo, CT, image intensifier and photo timing measurements
  • Automatic exposure reset for hands off operation
  • Rechargeable Ni-Cd batteries provide more than six hours of continuous service
  • RS-232 computer interface
  • Storage scope output for real-time waveform display
  • Reversible display for fluoro measurements

  Product Specifications
 
  Kilovoltage  Accuracy: 1 kV Mo/Mo (22 to 35 kVp Mammo generators w/30 μ Mo

 Range: W/Al Tubes: 27 to 155 kVp Mo/Mo Tubes: 21 to 50 kVp

  Time
 Description: Measured during entire exposure at 90% rise/fall of
 waveform

 Accuracy:
Within 2% or 2 ms, whichever is greater

 Range: 1 ms to 10 seconds
 
  Exposure
 Description: Measure during entire exposure; kvp corrected

 Accuracy: ± 5%

 Range: 10 mR to 10 R
 

  Fluoroscopic
  Rate

 Description:
Measured over one second intervals during fluoro exposure

 Accuracy: ± 5%

 Range: 0.5 to 200 R/min
 

  Detectors
 kV:
CsI/photodiode pair measures x-ray transmission through differential
 attenuators

 
Time: Computed from kV waveform stored in memory against quartz
 crystal time base

 
Exposure: Parallel plate ionization chamber

 Volume: 36 cm3

 Window: 38 mg/cm2, 18.9 cm2 polycarbonate

 Calibration: Reference to a NIST traceable voltage divider and a
 calibrated exposure monitor during irradiation
 

  Display
 1
6 character dot-matrix LCD
 
  Controls
 Description:
Model 4000+ has five rocker switches

 On/Off: Power switch

 Radio/Fluoro: Select radiographic or fluoro operation

 High/Low: Select for sensitivity

 Roll: Roll thru data

 Exposure/All: Select exposure only for external ion chamber

 Mo/Mo or W/Al: Select anode/filter of x-ray tube
 

  Connectors
 Power:
9 VDC, 500 mA

 Scope: BNC for oscilloscope connectio

 RS-232: DB-9 connector configured as DCE. BNC and banana plug for
 external Ion chamber
 

  Power
Requirements

 9 VDC 500 mA external supply. Rechargeable internal Ni-Cd batteries
 supply more than six hours of continuous service with overnight charge
 
 Dimensions
 8.5 (w) x 9 (d) x 3 in (h) (21.5 x 23 x 7.6 cm)
 
 Weight
 Approximately 3.5 lb (1.59 kg)
 
 HVL set
 Aluminum filters: 2.3, 1.0, and 0.3 mm
 
 External  
 Chamber 
 Accessories

 Radiographic Ion Chamber, 30 cm3

 (Victoreen Model 6000-528): energy response: within 7% from 30 to 150
 kVp (15 to 65 keV); cable: 15 ft (4.5 m); chamber dimensions: 4 x 4 x
 0.54 in thick (10.2 x 10.2 x 1.4 cm)

 Mammographic Ion Chamber, 3.3 cm3

 (Victoreen Model 6000-529): energy response: within 5% from 0.2 to 5.0
 mm Al HVL (16 to 90 kVp); cable: 15 ft (4.5 m); chamber dimensions: 4 
 cm Ø x 1.5 cm thick. This chamber meets the needs of the MQSA for an
 external transparent chamber. Option: Probe Holder (Model 6000-529-95)
 for BRH2 test stand

 Image Intensifier Ion Chamber, 150 cm3

 (Victoreen Model 6000- 530B): energy response: ± 10% from
 1.8 to 10mm Al HVL; cable: 10 ft (3.0 m); chamber dimensions:
 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm)

 Scatter Ion Chamber, 400 cm3

 (Victoreen Model 6000-532B): energy response: ± 5% from 32 to 662  
 keV; cable 10 ft (3.0 m); chamber dimensions: 6.26 x 8 x 0.63 in
 (15.9 x 20.6 x 1.6 cm)

 CT Ion Chamber, 3.2 cm

 
(Victoreen Models 6000-100 and 500-100): energy response:
 ± 5% from 1 to 10 mm Al HVL; cable: 3 ft (0.9 m); sensitive length:
 4 in (10.0 cm); chamber inside Ø: 0.25 in (6.4 mm)

 CT High Sensitivity Ion Chamber, 10 cm3, for multislice CT

 (Victoreen Models 6000-200 and 500-200): energy response:
 ± 5%from 1 to 10 mm Al HVL; cable: 3 ft (0.9 m); sensitive length:
 4 in (10.0 cm); chamber inside Ø: 0.45 in (11.44 mm)

 

 


  Model Name
 
  Power Adapter

  4000M+
 

 X-Ray Test Device with AC adaptor
 (specify from the following)

 USA/Japan: 110 VAC 9 VDC 500 mA (14-301)

 Europe: 230 VAC 9 VDC 500 mA (14-339)

 UK: 230 VAC 9 VDC 500 mA (14-415)

 Australia: 230 VAC 9 VDC 500 mA (14-415) and  
 adapter (14-416)
 

 


  Related Products
 
 4000EXL  Toolkit for Excel  RS232 Cable  190004
 07-434  Ultra-High purity HVL Attenuators
 Carrying Case
 

 4000-69

 

 

4000EXL Toolkit for Excel

The Victoreen® 4000 Toolkit for Excel is a complete software package for the 4000M+ NERO® that includes an Excel Add-In, called 4000 Add-In and Excel templates that may be used to evaluate the performance of radiographic, mammographic and fluoroscopic x-ray machines. The 4000 Add-In collects measured results from the 4000M+ NERO and places the data in the cells of the active Excel worksheet, starting at the active worksheet cell. The 4000 Add-In also may be used to acquire and graph radiation and kV waveforms from the 4000M+ NERO as well as remotely control the 4000M+ NERO.

Key Features

  • Automatically collects measurement results and places them in an Excel worksheet
  • Captures radiation and kV waveforms and charts them in an Excel worksheet
  • Templates are provided for QA tests on radiographic, fluoroscopic, and mammographic X-ray machines
  • Templates may be modified to perform user specific tests and generate user customized reports
  • Allows complete remote control of the Model 4000M+ NERO • Complete on-line help speeds learning
  • Compatible with Windows® 95, 98, ME®, NT® 4.0, 2000, and Microsoft® Excel 95, 97, 2000
  • Automatically detects the presence of Model 4000M+ NERO


 


  Product Specifications
 

  Templates
 

Radiographic Template performs these tests:

• Reproducibility• kVp accuracy• Timer accuracy• Linearity• Beam quality

Mammographic Template performs these tests:

• kVp accuracy• kVp reproducibility• Beam quality• Breast entrance exposure• AEC reproducibility• Average glandular dose• Radiation output rate

Fluoroscopic Template performs these tests:

• kVp accuracy• Beam quality• Fluoro exposure rate
 

 Functions  

Controls

The 4000 menu provides an interface for the user to remotely control the 4000M+ NERO and retrieve radiation and kVwaveforms.

A description of each menu option follows:

Remote Control

Selects the 4000M+ NERO measurement mode and measurement options. This allows the user to select the correct measurement mode for the template in use. For instance, the radio mode is selected when using the radiographic template, the Mo/Mo target filter is selected when using the mammographic template and the fluoro mode is selected when using the fluoroscopic template

Retrieve Rad Waveform

Retrieves the radiation waveform data from the 4000M+ NERO and charts it in a new Excel chart

Retrieve kV Waveform

Retrieves the kV waveform data from the 4000M+ NERO and charts it in a new Excel chart

 System requirements  Microsoft Windows 95, 98, ME, NT 4.0, 200. Microsoft Excel 95, 97, 2000. One serial port (COM1 through COM4)

 

07-434 Ultra-High Purity HVL Attenuators

  • HVL attenuators recommended for mammography
     
  • 99.9% pure for accurate HVL

Because type-1100 aluminum is only 99.0% pure, it has some impurities that can give a HVL value which is 7.5% lower than those measured with pure aluminum. When doing HVL measurements with a mammography unit, it is recommended that the highest purity aluminum be used. This set of six attenuators satisfies this recommendation, because they are 99.9% pure (type-1145).

Specifications
Dimensions: 10 cm x 10 cm x 0.1 mm

Weight: 0.15 lb (0.06 kg)

 

 


  Model Name
 
  Description
 07-434
 
Ultra-High Purity HVL Attenuators, set of 6
 
 07-430
 
Standard Aluminum HVL Attenuators, set of 11
 

 07-431
 

 
Copper HVL Attenuators, set of 10
 

 

 

    

Supertech ®

 

  Address:
  P.O. Box 186
  Elkhart, IN 46515 USA


  Sales: 800-654-1054
  Phone: 574-264-4310
  Fax: 574-264-9551


Email:
sales@supertechx-ray.com
Support: support@supertechx-ray.com