Nested CT Dose Phantom Kit for Pediatric/Adult
Head and Body
Model 76-424-4156
Introduction
The innovative nested CT Dose Phantom can be used with any computed tomography (CT) system designed to image pediatric and adult head and body.Each phantom segment can provide separate dose information. When performing dose profile measurements, the dose phantoms allow the user to
Diagnostic Imaging
- Uniquely designed for pediatric and adult computed tomography dose index (CTDI) in a lightweight (44 lb, 20 kg) total package
- Can be used with new multi-detector (MDCT) units
- Meets requirements of FDA performance standards
- All new carrying case with wheels and pull handle
- Case includes space for CT Ion Chambers (purchased separately)
tomography (CT) system designed to image pediatric and adult head and body. collect information for the maximum, minimum and mid-range value of the nominal tomographic section thickness. This essential phantom kit consists of three parts: an adult body phantom, an adult head phantom that doubles as a pediatric body phantom and the new pediatric head phantom, nested together for easy storage and convenient transport. (All are made of solid acrylic with diameters of 32, 16 and 10 cm, respectively.) Each part contains four probe holes around the perimeter, 90° apart and 1 cm from the edge and the pediatric head (center insert) has one probe hole in its center. The inside diameter of the holes is 1.31 cm. Each part includes five acrylic rods for plugging all the holes in the phantom. A sturdy storage and carrying case with wheels and pull handle that holds all three phantoms is included; as an option, a smaller case without wheels is available.
Applications
The CT Dose Phantoms were designed in accordance with the Food and Drug
Administration’s performance standard for diagnostic x-ray systems, which includes regulations specifically applicable to CT systems (21 CFR 1020.33).Specifications
WeightAdult body phantom 25 lb (11.3 kg)
Adult head/pediatric body phantom
5 lb (2.3 kg)
Pediatric head phantom 3 lb (1.3 kg)
3 nested phantoms 33 lb (15 kg)Dimensions
Adult body phantom 15.5 cm long x 32 cm Ø
Adult head/pediatric body phantom
15.5 cm long x 16 cm Ø
Pediatric head phantom 15 cm long x 10 cm ØAvailable model(s)
76-424-4156 Nested CT Dose Phantom
Kit for Pediatric/Adult Head and Body
including carrying case with wheels and
pull handle
76-424-4150 Nested CT Dose Phantom
Kit for Pediatric/Adult Head and Body
including carrying case without wheels and pull handleOther CT Dose Phantoms available
76-419-4150 CT Dose Phantom Kit for
Pediatric/Adult Head and Body including carrying case with wheels and pull handle
76-419 CT Pediatric Head Dose Phantom with five plugs
76-414 CT Head Dose Phantom with five plugs
76-415 CT Body Dose Phantom with five plugsFor ion chamber selection, see next page.
CT Ion Chambers
Specifications for 10 cc high sensitivity
Detector type Vented air ion chamber
Volume 10.1 cc
Sensitive length 10.0 cm
Chamber material Acrylic (PMMA)
Chamber outside diameter
0.5 in ± 0.015 in
(12.7 mm ± 0.4 mm)
Chamber inside diameter 0.45 in (11.44 mm)
Chamber wall thickness 77 mg/cm2
Electrode material Aluminum, 1100
Sensitivity 3.2 R•cm/nC (nominal) or 0.3/nC
Standard calibration 100 kVCP, 5.5 mm Al HVL (NIST Tech. M100)
Response uniformity along axis ± 3% over central 90% of active length
Beam orientation Normal to chamber axis
Leakage current (300 V collection potential) Less than 10-14 A at
10 min polarization time
Intensity limits Continuous beam: 31.6 R/sec, (1% recombination loss)
Pulsed beam 15.8 mR/pulse (1% recombination loss)
Collection time 0.478 mSec
Cable length 3 ft (0.9 m)
Operating voltage - 300 V
Specifications for 3.2 cc
Detector type Vented air ion chamber
Volume 3.2 cc
Sensitive length 10.0 cm
Chamber material Polystyrene
Chamber inside diameter 6.4 mm
Chamber wall thickness 54 mg/cm2
Electrode material Aluminum
Sensitivity 10 R•cm/nC (nominal)
Standard calibration 100 kVCP, 5.5 mm Al HVL (NIST Tech. M100)
Response uniformity along axis ± 3% over central 90% of active length
Beam orientation Normal to chamber axis
Phantom adapter OD 1.27 ± 0.04 cm (0.50 ± 0.015 in)
Leakage current (300 V collection potential) Less than 1013 A at
10 min polarization time, less than 1014 A at 2 hr polarization time
Intensity limits Continuous beam: 4.86 kR/min (1% recombination loss)
Pulsed beam 51.5 mR/pulse (1% recombination loss)Typical energy dependence for 3.2 cc ion chamber
(phantom adapter removed)
Maximum pulse repetition rate 3.3 kHz
Cable length 3 ft (0.9 m)
Operating voltage - 300 VAvailable model(s)
660-6 CT Ion Chamber, 3.2 cm3, with UHF termination: used with Victoreen® Model 660 Electrometer
500-100 CT Ion Chamber, 3.2 cm3, with coax BNC for signal & banana plug for bias: used with Model 35040 (ATD), TRIAD™ and TRIAD TnT
500-200 CT Ion Chamber High Sensitivity, 10 cm3 for multislice CT, with coax BNC for signal & banana plug for bias: used with Model 35040 ATD and other electrometer/dosimeters, including TRIAD and TRIAD TnT
6000-100 CT Ion Chamber, 3.2 cm3, with triax BNC: used with Victoreen Models 4000, 6000, 8000 and RAD-CHECK® PLUS
6000-200 CT Ion Chamber High Sensitivity, 10 cm3, for multislice CT, with triax BNC: used with Victoreen Models 4000, 6000, 8000
and RAD-CHECK PLUS
CT Dose Phantom Kit for
Pediatric/Adult Head and Body
Model 76-419-4150Allows the user to calculate:
- Computed Tomography Dose Index (CTDI)
- Dose profile
- Meets requirements of FDA Performance Standards
Introduction
These phantoms can be used with any computed tomography (CT) system designed to image both head and body.
They can separate dose information for each. When performing dose profile measurements, the dose phantoms allow the user to collect information for the maximum, minimum and mid-range value of the nominal tomographic section thickness.
This essential phantom consists of two parts: a body phantom and a head phantom. Both are made of solid acrylic, 15 cm thick, with diameters of 32 cm and 16 cm, respectively. Each part contains
five probe holes, one in the center and four around the perimeter, 90° apart and 1 cm from the edge. The inside diameter of the holes is 1.31 cm. Each part includes five acrylic rods for plugging all the holes in the phantom. A storage and carrying case is available for your convenience.
Applications
The CT Dose Phantoms were designed in accordance with the Food and Drug Administration’s performance standard for diagnostic x-ray systems, which includes regulations specifically applicable to CT systems (21 CFR 1020.33).
- Specifically designed for pediatric and adult computed tomography dose index (CTDI)
- Can be used with new multi-detector (MDCT) units
- Meets requirements of FDA performance standards
- All new carrying case with wheels and pull handle
Specifications
Weight Body phantom: 32 lb (14.5 kg);
Head phantom: 8 lb (3.6 kg)
Optional accessoriesCarrying Case (Model 89-414)
CT Head Dose Phantom with five plugs
(Model 76-414)
CT Body Dose Phantom with five plugs
(Model 76-415)Available model(s)
76-414-4150 CT Dose Phantom Kit for Adult
Head and Body, including carrying case
CT Ion ChambersSpecifications
Detector type Vented air ion chamber
Volume 3.2 cc
Sensitive length 10.0 cm
Chamber material Polystyrene
Chamber inside diameter 6.4 mm
Chamber wall thickness 54 mg/cm2
Electrode material Aluminum
Sensitivity 10 R. cm/nC (nominal)
Standard calibration 100 kVCP, 5.5 mm Al HVL (NIST Tech. M100)
Energy response ± 5%, 1 mm Al to 10 mm Al HVL
Beam orientation Normal to chamber axis
Phantom adapter OD 1.27 ± 0.04 cm
(0.50 ± 0.015 in)
Leakage current (300 V collection
potential) less than 1013 A at 10 min
polarization time, less than 1014 A at 2 hr polarization time
Intensity limits Continuous beam: 4.86 kR/min (1% recombination loss)
Pulsed beam 51.5 mR/pulse
(1% recombination loss)
Maximum pulse repetition rate 3.3 kHz
Cable length 3 ft (0.9 m)
Weight 1 lb (0.46 kg)Available model(s)
660-6 CT Ion Chamber, 3.2 cm3, with
UHF termination: used with Victoreen®
Model 660 Electrometer
500-100 CT Ion Chamber, 3.2 cm3: used
with Model 35040 (ATD)
500-200 CT Ion Chamber High
Sensitivity, 10 cm3: used with Model
35040 (ATD) and other electrometer/
dosimeters
6000-100 CT Ion Chamber, 3.2 cm3: used
with Victoreen Models 4000, 6000, 8000,
and RAD-CHECK® PLUS
6000-200 CT Ion Chamber High Sensitivity, 10 cm3, for multislice CT: used with Victoreen Models 4000, 6000, 8000,
and RAD-CHECK PLUS
Supertech ®
President: David B. McNitt
V.P. of Marketing: Judy McNitt-Mell
Asst. to the President: Joy E. NystrandAddress:
P.O. Box 186
Elkhart, IN 46515 USA
Sales: 800-654-1054
Phone: 574-264-4310
Fax: 574-264-9551
Email: sales@supertechx-ray.com
Support: support@supertechx-ray.com