AAPM CT Performance Phantom Model 610
Meets guidelines in AAPM Report #1 "Performance
Evaluation and Quality Assurance of CT Scanners"

 

Model 610

Measurement Capabilities

                        • Noise
                        • Size Independence
                        • Sensitivity / Detectablity
                        • Radiation Dose
                        • Mechanical Alignment
                        • Spatial Uniformity
                        • Beam Hardening
                        • HU Linearity
                        • Slice Thickness
                        • Spatial Resolution and
                           line spread function

 

The CIRS Model 610 AAPM CT Performance Phantom offers the user a single test
object that measures ten distinct CT performance parameters. The phantom design
is based on the guidelines presented in Report #1 of the American Association of
Physicists in Medicine Task Force on CT Scanner Phantoms. The goals of report #1
were to “(1) define ‘performance’ of a CT scanner and (2) describe methods of
performance testing through utilization of particular phantoms.”
A CT number linearity insert, high contrast resolution insert and slice width insert are
housed in an 8.5 “ diameter PMMA water tank with quick disconnect valves for ease of
filling and draining between use. Also included is a 0.25” bone equivalent ring that can
be fit over the inserts to evaluate the effects of beam hardening.
A contrast test object is adhered to the bottom of the tank that includes two rows of
cavities from 1 to 0.125” diameter. The cavities can be filled with various solutions for
contrast evaluation. An aluminum alignment insert is incorporated in the lid of the tank
and can be swapped with a polystyrene TLD insert for dose measurements.
A user’s manual, holding cradle, filling tubes and other accessories are included.

Optional items:
Low contrast test object insert
External whole-body resolution / noise ring
Foam lined carry case.
 

Specifications: