Supertech ®
Thousands of Products
Serving You is Our Pleasure

Home

Registered w/
Dun & Bradstreet 

WOSB - Woman Owned Small Business
Established 1973


Product Categories

 
  Supertech's
  X-ray Technique Calculator
  Alderson Phantoms
  Anesthesiology
  Anthropomorphic Phantoms
  Aprons and Barriers
  BIODEX Tables
  Breast Imaging/Care/Mammo
  Chairs
  CT
  Filters
  First Resp./Homeland Security
  L-Blocks and Shields
  Mammography
  MRI
  Multi-Modality Phantoms
  Nuclear Medicine
  Patient Positioning
  Quality Control Instrumentation
  Quality Control Phantoms
  Radiation Protection Eyewear
  Radiation Survey Meters
  Radiation Therapy
  Radiopaque Rulers
  Ultrasound
  X-Ray Technique Calculator
 

 

Digital kVp Meters
Wide-Range Digital kVp Meters 07-494 &
Digital Mammographic kVp Meters 07-492

Whether you choose the Wide-Range or Mammographic Digital kVp Meter, you will get quick and accurate measurements of your diagnostic x-ray generator tube potential. These instruments need no connection to the x-ray generator.

These lightweight, rugged units are extremely easy to use: simply place on the x-ray table, with the detector facing the x-ray source. With the beam’s central ray centered on the detector, an exposure is made, and the reading appears immediately on the large, easy-to-read liquid crystal display. Unique features are provided to ensure maximum efficiency and accuracy. Readings remain on display until the next exposure is made, at which time the reading is automatically updated.

Automatic display indicators tell you when adjustment of exposure factors or battery replacement is necessary. Neither remote-control cables nor time-consuming manual re-zeroing are needed. A BNC connector is provided for radiation waveform display on a storage oscilloscope.  

Product Specifications
Ranges Wide Range:

Low: 50 kVp to 90 kVp, 0.1 kVp resolution High: 80 kVp to 150 kVp, 0.1 kVp resolution

Mammographic: 24 kVp to 40 kVp, 0.1 kVp resolution

Accuracy Wide Range: ± 3% or 3 kVp (whichever is greater)

Mamographic: ± 3% or 1.5 kVp (whichever is greater)

mAs requirements Wide Range: (45.7 cm SDD) 18 mAs at 120 kVp; 50 mAs at 60 kVp, single phase. Minimum exposure time 1/20 (0.05) sec

Mammographic: (25 cm SDD) 100 mAs at 24 kVp. Minimum exposure time 1/20 (0.05) sec

Controls Wide Range: On/off, single/three-phase and range selection switch

Mammographic: On/off and Moly/Tungsten selector switches

Operating temperature 10 ºC to 40 ºC (50 ºF to 104 ºF)
Relative humidity 0% to 90%, noncondensing
Power requirements 9 V alkaline battery, 150 hours operation
Display 3.5 x 0.5 inch LCD. Automatic indication of (a) low battery condition, (b) need to adjust exposure factors
Output signal BNC connector for waveform analysis
Dimensions(WxDxH) 20 cm x 15 cm x 6 cm (8 in x 6 in x 2.5 in)
Weight 0.9 kg (2 lb)

 

Model Name Description
07-494  Wide-Range Digital kVp Meter
07-492  Mammographic Digital kVp Meter

 

Carrying Cases
89-473 Carrying Case
 

 

    

Supertech ®

 

  Address:
  P.O. Box 186
  Elkhart, IN 46515 USA


  Sales: 800-654-1054
  Phone: 574-264-4310
  Fax: 574-264-9551


Email:
sales@supertechx-ray.com