Supertech ®
Thousands of Products
Serving You is Our Pleasure

Home

Registered w/
Dun & Bradstreet 

VOSB - Veteran Owned Small Business since 1973   NAICS CODE: 423450


Product Categories

 
  Supertech's
  X-ray Technique Calculator
  Alderson Phantoms
  Anesthesiology
  Anthropomorphic Phantoms
  Aprons and Barriers
  BIODEX Tables
  Breast Imaging/Care/Mammo
  Chairs
  CT
  Eyewear
  Filters
  First Resp./Homeland Security
  L-Blocks and Shields
  Mammography
  MRI
  Multi-Modality Phantoms
  Nuclear Medicine
  Patient Positioning
  Quality Control Instrumentation
  Radiation Survey Meters
  Radiation Therapy
  Radiopaque Rulers
  Ultrasound
  X-Ray Technique Calculator
  Continuing Ed / CEU

 

The Lawrence Livermore Realistic Phantom
A Worldwide Reference Standard for In-Vivo Counting

Fission-Product and Thyroid Phantoms

The Lawrence Livermore Realistic Phantom was developed under the direction of the U.S. Department of Energy, primarily as a reference standard for the in-vivo counting of emissions from low-energy transuranic nuclides.

The organs of interest are the lungs, liver and lymph nodes. Each of these may be radioactive or inert. These organs are accommodated in a male thorax generally similar to average adult males.

 

 

The Livermore phantoms contains a synthetic bone skeleton molded within a soft-tissue-equivalent material. The organs are located in an internal cavity with a separate torso cover that closes the phantom. Anterior sections of ribs and the sternum are molded into this cover.

Soft-tissue-equivalent blocks are used to position the organs and fill significant air spaces, providing continuity of the soft-tissues throughout the phantom. The phantom is shipped assembled with inert organs. Any or all of these organs can be replaced with radioactive organs, which are shipped in separate packages.

Organs
All organs are made of soft-tissue equivalent materials. Lungs are available with the nuclides uniformly dispersed throughout the lung molding material. Optional organs (developed by RSD and not part of the original DOE specifications) are inert, but have holes in 2 cm
2 grids. These either can be filled with inert plugs or with active capsules to establish any desired distribution within the lungs.
 
Lungs Chest Overlay Plates

The liver has the same loading flexibility, but another options is available, designed for use with solutions having relatively short half-lives. This liver is a hollow shell with a fill/drain port.

If the liver is not required, it may be replaced with the Abdominal Contents, which are also available with a hole matrix, or active.

Lymph nodes are available as hollow shells or as active packets. Two are 8 mm in diameter by 17 mm long. A third is 13 mm in diameter by 25 mm long. They are positioned in recesses molded in a lymph mode block.

Chest Overlay Plates
Transuranic emissions from individuals with varying amounts of muscle and/or adipose tissue may be so attenuated as to be undetectable. Chest overlay plates were developed to ensure the validity of in-vivo counting of such individuals.

There are three sets of plates, each in four graded thicknesses. One set is equivalent to 87% adipose and 13% muscle, another is equivalent to 50% muscle, and the third is equivalent to 100% muscle. Plates of each material and/or each thickness are available separately.

Targets
Three sets of concentric circles are drawn in permanent black ink over the torso cover and over each chest overlay plate. They range in 1 in. increments from 1 in. to 5 in. in diameter, with a 5.5 in. diameter outer circle. One set of circles is places over each lung region, with the outer circle tangent to the inferior aspect of the clavicle and protruding over the sternum. The third set is placed over the liver.

A 2 cm2 grid is projected in red ink over most of the chest surface by the same technique that is used for the circles. All targets are consistent among all phantoms.

 

  Livermore Organs
  Organs   Inert, Hole Matrix   Solid, Active   Inert, Hollow
  Lungs   N/A   RS-503A   N/A
  Lymph Nodes
  (set of 3)
  N/A   RS-506A   RS-506S
  Liver &
  Liver Envelope
  RS-507H   RS-508A
  (Liver only)
  RS-519S
  (Liver only)
  Abdominal
  Contents*
  RS-510H   RS-511A   N/A

* Replaces Liver and Liver Envelope

 

Chest Overlay Plates

RS-513 Chest Overlay Plate (Any of 4 thicknesses)
(1,2,3,4) #1 - thinnest, #4 - thickest
(A,B,C)  A) 87% adipose - 13% muscle
             B) 50% adipose - 13% muscle
             C) 100% muscle

RS-514 Chest Overlay Plates
(A,B,C) Set of 4, in materials A, B or C

 

     Supertech ®

  President: David B. McNitt
  V.P. of Marketing: Judy McNitt-Mell
  Asst. to the President: Joy E. Nystrand

  Address:
  P.O. Box 186
  Elkhart, IN 46515 USA


  Sales: 800-654-1054
  Phone: 574-264-4310
  Fax: 574-264-9551


Email:
sales@supertechx-ray.com
Support: support@supertechx-ray.com