Surgical C-Arm Table Biodex 058-840
Three-axis motorized positioning plus X-Y free-float. Ideal for cardiovascular procedures.

058-840 Rectangular Top
Rectangular Top
058-840 Contoured Top
Contoured Top
Accomodates Bariatric Patients

The Surgical C-Arm Table 840 is designed for image-guided fluoroscopic procedures where stability, access, and precise, quiet, vibration-free positioning are essential. A cantilevered low attenuation carbon fiber tabletop, with choice of rectangular or contoured design, accommodates portable or ceiling-suspended C-Arms. The rectangular top offers additional space to allow for superior image quality for long-leg runoff studies. The contoured top provides ample workspace for anesthesiologists, yet the narrowness required for cervical procedures. Choose the top that best suits your needs to achieve optimum image resolution.

The extra-large, 71" radiolucent area, free-float X-Y tabletop, motorized control of height, isocentric lateral roll, Trendelenburg motions and the catheter tray extension make the Surgical C-Arm Table - 840 ideal for cardiovascular procedures. The radiolucent area is free of cross members, allowing full fluoroscopic visualization and unobstructed C-Arm positioning. Functional design provides complete access with reduced radiation exposure to clinicians. Patient comfort and stability are assured by two-inch thick table padding and three adjustable straps with hook and loop fastening. The contoured tabletop features a face cutout for prone positioning.




058-840 Rectangular Top
Shown in 20° Trendelenburg
 
058-840 Rectangular Top
Optional Disposable Bellows Skirt
protects against contamination
058-840 Rectangular Top
Catheter Tray Extension - This feature makes the
procedure easier, safer and reduces the risk
of breaking the sterility of the catheters

Control Made Easy

The portable hand-held and foot-operated controllers ensure quick and safe tabletop positioning, and can be positioned from any point around the table. Both controllers offer the freedom to adjust height, lateral roll and Trendelenburg motions. The hand-held controller provides the back-to-level function. The foot-operated controller also releases the tabletop for X-Y positioning and is ideal when hands are busy with other functions.

Freedom of Movement

The ergonomic mushroom-shaped control optimizes command of the SmoothGlide™ free-float tabletop. When employing any degree of tilt or roll, X and Y positions are "locked" to prevent gravity-induced movement. Selective "lockout" of X or Y movement is also provided: 35" head-to-toe (X) can be maintained during lateral roll; and side-to-side (Y) can be maintained during Trendelenburg positioning. Isocentric lateral roll is a unique movement that maintains center of the focal area, minimizing image distortion. Reducing the time required for adjustments, table or patient, ultimately reduces exposure to scatter radiation.

As required by law, all Biodex C-Arm tables are CDRH registered and FDA Device Listed. All motorized tables are ETL product listed to the UL-60601-1 Medical Electrical Equipment Safety Standard.

Features:

Stable, Accessible, Precise, Quiet, and Vibration-Free Positioning! Quick, safe control.
Hand-Held Controller
Hand-Held Controller

The portable hand-held and foot-operated controllers offer the freedom to adjust height, lateral roll, and Trendelenburg motions. The foot-operated controller also releases the tabletop for X-Y positioning and can be used when hands are busy with other functions. The hand-held controller hangs on an accessory rail when not in use.

Foot Controller
Foot Controller
Mushroom-Top Control
Mushroom-Top Control
The ergonomic mushroom-shaped control optimizes command of the SmoothGlide™ free-float tabletop. When employing any degree of tilt or roll, X and Y positions are “locked” to prevent gravity-induced movement. Selective "lockout" of X or Y movement is also provided: 35" head-to-toe (X) can be maintained during lateral roll; and side-to-side (Y) can be maintained during Trendelenburg positioning.

Choice of Tabletop Design

INNOVATIVE CONTOUR DESIGN TOP

This design fully accommodates C-Arm positioning for closest possible access to the cervical spine, achieving optimum image resolution. A second benefit is the added workspace at the head end, while maintaining the narrowness required for cervical procedures. Features a cutout for comfortable, prone positioning.

RECTANGULAR TABLETOP

The rectangular tabletop offers additional space to allow for superior image quality for long-leg runoff studies.

Specifications
Models and Ordering
058-840 Table, Surgical C-Arm - 840, Contour, 115 VAC
058-840-10 Table, Surgical C-Arm - 840, Rectangle, 115 VAC
058-845 Table, Surgical C-Arm - 840, Contour, 230 VAC
058-845-10 Table, Surgical C-Arm - 840, Rectangle, 230 VAC
Optional
058-864 Arm Board, Surgical, Carbon Fiber
056-866 Arm Board, Carbon Fiber, two arms
Fits Surgical C-Arm Tables 840, 846 and 870 Pain Management Table
056-865 Arm Board, Carbon Fiber, one arm
056-850 IV Pole, Rail Mounted
058-849 Clamp, Accessory, C-Arm Table
058-856 Radiation Shield, Head/Cervical
058-857 Radiation Shield, Thoracic/AB
056-862 Battery and Charging Unit, 115 VAC
056-863 Battery and Charging Unit, 230 VAC
056-802 Bellows Skirt, disposable plastic, 250/roll
Fits Surgical C-Arm Tables 840, Urology C-Arm Table and Brachytherapy Table
Biodex Delivery Options for all Imaging Tables*
Dock-to-Dock Delivery - the quickest and most economical delivery service. Requires a raised loading dock at delivery address.
White Glove Service - Inside, full-service delivery. Table is uncrated and brought to customer designated area. All debris is removed. Loading dock is not required.
Future Delivery - Request delivery of imaging table for a specified future date. Indicate on P.O. when delivery is preferred along with type of delivery.
Charges for delivery services apply. Ask for details when placing your order.
*Offered in the US only.

Surgical C-Arm Table Biodex 058-840
 
 
 
 